Manufacturing · Next-generation modular data centers

Modular data center
High-efficiency cooling for high-density racks

We don't spend energy cooling the entire volume of the data center — we remove heat directly from each IT rack. The air conditioner is only a backup and peak-load circuit; energy-efficient free cooling does the main work.

Density 35 kW per rack
PUE 1,1 vs. 1.7
Module 140 kW IT

Prototype.

16 images · Carousel

→ Swipe right to see all images

Technology
of direct heat removal

Patented technology
Domestic components

01 · Description

Modular digital data processing center

A container-type metal structure for high-power server equipment that delivers higher cooling efficiency without increasing energy consumption. 140 kW of IT per module, with heat removed directly from the racks to the outside. Pay for cooling the equipment, not the room.

Data center interior: diesel generator and climate control system [ CIRCUIT 01 ]

02 · Design

Two thermally insulated cavities

The upper one takes in outside air and delivers it to the cooling zone; the lower one houses the IT equipment. No need for hot/cold aisles or expensive air conditioners.

IP55

Enclosure protection rating

03 · Cooling

No liquid cooling or in-row air conditioners

Based on controlled airflow and natural thermodynamics. The air conditioner is only a backup and peak-load circuit.

35 kW

Per rack, air-cooled

04 · Standard configuration

Module specification

Dimensions 9000×3200×3200 mm. 4 racks, 600×1200×33U. 180 kW UPS with batteries. 3G+5G filters. Fire protection system. SCADA: inlet/outlet temperature of each rack, airflow, fan speed, pressure, humidity, damper and platform positions, air conditioner mode.

UHL1

Climate range −40…+50 °C

→ Full specification in the technical brief

Request a spec Who it's for

Target industries

Who it's for

MegaShield modular data centers are built for organizations where infrastructure failure is unacceptable and the deployment site is far from the main data center. Reliable outdoor operation without hangars — ideal for remote sites.

Industries 04 sectors
Efficiency PUE 1,1
  1. 01.

    Banking and finance

    Backup data centers: hot standby for core banking systems with automatic failover, compliant with Central Bank geo-redundancy requirements.

  2. 02.

    Telecom operators

    Edge nodes for traffic processing at base stations: content caching, local routing, and 5G infrastructure in self-powered modules.

  3. 03.

    Industrial holdings

    Remote extraction and processing sites: process control systems, SCADA, video surveillance, and data processing in the field without building permanent server rooms.

  4. 04.

    Public sector

    Secure computing clusters for government agencies: outdoor operation without hangars, deployment in any region of Russia, domestic components.

Product line

Product line

Products

Four models, from a single rack to an industrial cluster. All support 10 to 35 kW per rack and scale without downtime. Price depends on load and the technical brief.

01
MegaShield S — compact single-rack cooling module

Starter

MegaShield S

1 rack, up to 35 kW IT. Ideal for pilot launches and small sites.

Racks 1
Power 35 kW
Price RUB 20–30 million
02
MegaShield M — standard 4-rack module

Standard

MegaShield M

4 racks at 35 kW each, up to 140 kW IT. Pilot project: RUB 40–60 million.

Racks 4
Power 140 kW
Price RUB 50–80 million
03
MegaShield L — extended 8-rack module

Extended

MegaShield L

8 racks at 35 kW each, up to 280 kW IT. Fast scaling of an existing facility.

Racks 8
Power 280 kW
Price RUB 95–150 million
04
MegaShield XL — 16-rack industrial cluster

Industrial

MegaShield XL

16 racks at 35 kW each, up to 560 kW IT. Industrial scale on a single site.

Racks 16
Power 560 kW
Price RUB 180–290 million

How we work

Timeline

4 stages · 4 to 5 months to launch

  1. 01/04

    Design

    Every client requirement is taken into account in the design. We calculate the climate zone, IT load, and operating mode for the specific site.

    • Brief
    • Climate calculation
    • 3D model
    Duration 3 weeks
  2. 02/04

    Manufacturing

    Modular enclosure (IP55), direct heat removal system, control unit, power wiring, UPS, batteries, and monitoring system (SCADA).

    • IP55 enclosure
    • Fans
    • UPS + batteries
    • SCADA
    Duration 4–5 months
  3. 03/04

    Installation

    Delivery and installation. Deployment in any region of Russia. Reliable outdoor operation without hangars.

    • Delivery
    • Placement
    • Connection
    Duration 1–2 weeks
  4. 04/04

    Commissioning

    Staff training: operating instructions. Warranty, service, and spare parts.

    • Commissioning
    • Training
    • Warranty
    Duration 3 days

Advantages · Economics

More computing power
within the same power limits

We don't just save electricity. We turn a site's limited electrical capacity into more computing power. 140 kW of IT per module, with heat removed directly from the racks to the outside.

  • 01

    PUE 1.1 vs. a typical 1.7

    Traditional data center: 200 kW = 118 kW IT at PUE 1.7. MegaShield: 200 kW = 182 kW IT at PUE 1.1. That's +64 kW of computing power without increasing the allocated capacity.

  • 02

    Savings of RUB 5.9 million per year

    At 140 kW IT: a traditional data center costs RUB 16.7 million per year, MegaShield RUB 10.8 million per year. Over 5 years that's RUB 29.5 million saved per module on cooling alone.

  • 03

    In-house manufacturing and patents

    Full quality control. Patented technology. Custom solutions for specific business needs. Domestic components. Fire resistance class K0 (REI 60–90 min), 50–60 dB sound insulation, simple maintenance with no liquid loops.

Climate chamber for testing the data center at extreme temperatures
[ PATENT · TECHNOLOGY ]
Mode: UHL1 −40…+50°C PUE: 1,1 Status: Patented

Contact · Brief request · Cost estimate

Contact us

Send us your technical brief — we'll estimate cost and timeline within 1 business day!